Single Sprinkler Minimum Pressureand Flow RequirementsFeaturesUtilizes a levered fusible alloy solder link.Eliminates in-rack sprinklers for 45’ high buildings.Lower flows offer opportunities to reduce:Interior PipingFire Pump SizesUnderground PipeTank SizesMaximum deflector distance from ceiling (roof) is 18”(457mm).Available in 165°F (74°C) and 212°F (100°C) – cULusListed and FM Approved.Available in 165°F (74°C) and 212°F (100°C) – VdSand LPCB Approved.

Product DescriptionThe HL22 Early Suppression Fast Response (ESFR)Sprinkler is intended for use against severe fire challenges.This sprinkler is designed to respond quicklyto growing fires with a high volume of water dischargeto “suppress” rather than “control” fires at lower pressuresand without in-rack sprinklers for 35’ (10.7m) to40’ (12.2m) storage as is required with a K14 or K17ESFR.The HL22 Sprinkler utilizes a levered fusible alloysolder link in either 165°F (74°C) or 212°F (100°C) temperatureratings. FM Global considers this a “QuickResponse” storage sprinkler for use in data sheet 8-9. The sprinkler has a Nominal K Factor of 22.4 (320metric) and will deliver approximately 112 gpm (424L/min) of water at 25 psi (1,7 bar).

The deflector and frame provide a broad, very symmetrical,hemispherical pattern capable of suppressingfires between sprinklers in high storage height areasand at the same time maintaining good central coredistribution to penetrate and suppress fires occurringdirectly beneath the sprinkler.Application and InstallationThe HL22 ESFR sprinkler is intended for installationin accordance with NFPA 13 and Factory Mutual (FM)Loss Prevention Data Sheets 2-0 and 8-9, as well as theAuthority Having Jurisdiction.This sprinkler is intended for protection of Class I toIV Commodities and Group A or B plastics, which includescartoned unexpanded plastics. The storagecan be palletized and solid piled, open frame singlerow or multiple row and portable rack storage.

Approvals Organizations (See following table)Listed by Underwriters Laboratories Inc. and UL certifiedfor Canada (cULus). Listed for installation in accordancewith NFPA standards for storage heights to 40ft. (12.2m)in buildings to 45ft. (13.7m) high.FM Approved as a storage sprinkler.The HL22 Sprinkler is for use in buildings with ceilings upto 45ft. (13.7m) high with storage heights to 40 ft. (12.2m)when installed in accordance with FM Loss PreventionData Sheets 2-0 and 8-9.NYC MEA 258-93-EVdS Schadenverhütung (VdS)Loss Prevention Certification Board (LPCB)

 

 

 

 

 

 

 

 

 

Posted in ESFR K22 | Leave a comment

JL-17 Early Suppression Fast Response(ESFR) Sprinkler

Product DescriptionThe Reliable Model JL-17 Early Suppression Fast Response(ESFR) Sprinkler is intended for use againstsevere fire challenges. This sprinkler is designed to respondquickly to growing fires and will deliver a heavywater discharge to “suppress” rather than “control”fires.Note: The Model JL-17 ESFR sprinkler utilizes a leveredfusible alloy solder link in either a 165°F (74°C)or a 212°F (100°C) rating. FM Global considers thisa “Quick Response” storage sprinkler for use in DataSheet 8-9.The sprinkler has a Nominal K Factor of 16.8 (metric241,9) and will deliver approximately 121 gpm (458 L/min) of water at 52 psi (3,6 bar).The smaller deflector and frame provide a broad, verysymmetrical, hemispherical pattern capable of suppressingfires between sprinklers in high storage heightareas and at the same time retaining a high momentumcentral core to penetrate and suppress fires occurringdirectly beneath the sprinkler in low storage height areas.The JL-17 ESFR sprinkler was designed to be shorter,and more compact than other ESFR sprinklers. Theshorter sprinkler allows piping to be installed further fromthe ceiling and obstructions. The JL-17 ESFR sprinkler isalso less susceptible to damage due to smaller deflectorand frame design. The lighter JL-17 ESFR passedrough use and abuse test in the labs without plastic protectors.Application and InstallationThe Model JL-17 ESFR sprinkler is intended for installationin accordance with NFPA 13 and FM Loss PreventionData Sheets 2-0 and 8-9, as well as the AuthorityHaving Jurisdiction.The Model JL-17 ESFR sprinkler is designed for ceilingonly sprinkler system with no in-rack sprinklers required.For encapsulated or non-encapsulated includingcartoned unexpanded plastics of up to 35 ft (10,7m)with ceiling heights to 40 ft (12,2m). Model JL-17 ESFRis also use for cartoned expanded plastics up to 25 ft(7,6m) with ceilings heights to 30 ft (9,1m) as well assome storage arrangements of rubber tires, rolled paper,and aerosols.For storage protection that have up to 40 ft (12,2m)storage heights with 45 ft (13.7m) ceiling heights, ModelJL-17 ESFR can be used with one level of in-rack sprinklers.

Posted in ESFR K17 | Leave a comment

JL-14 Early Suppression FastResponse (ESFR) Sprinkler

Product DescriptionThe Reliable Model JL-14 Early Suppression FastResponse (ESFR) Sprinkler is intended for use againstsevere fire challenges. This sprinkler is designed to respondquickly to growing fires and will deliver a heavywater discharge to “suppress” rather than “control”fires.Note: The Model JL-14 ESFR sprinkler utilizes a leveredfusible alloy solder link in either a 165°F (74°C)or a 212°F (100°C) rating. FM Global considers thisa “Quick Response” storage sprinkler for use in DataSheet 8-9.The sprinkler has a Nominal K Factor of 14.0 (metric202) and will deliver approximately 100 gpm (378 L/min)of water at 50 psi (3,5 bar).The deflector and frame provide a broad, very symmetrical,hemispherical pattern capable of suppressingfires between sprinklers in high storage height areasand at the same time retaining a high momentum centralcore to penetrate and suppress fires occurring directlybeneath the sprinkler in low storage height areas.Application and InstallationThe Model JL-14 ESFR sprinkler is intended for installationin accordance with NFPA 13 and FM Loss PreventionData Sheets 2-0 and 8-9 as well as the AuthorityHaving Jurisdiction.This sprinkler is intended for protection of palletizedand solid piled and open frame single row, double row,multiple row and portable rack storage of most commonmaterials including unexpanded and cartoned expandedplastics.The JL-14 ESFR sprinkler was designed to be shorter,and more compact than other ESFR sprinklers.The shorter sprinkler allows piping to be installed furtherfrom the ceiling and obstructions. The JL-14 ESFRsprinkler is also less susceptible to damage due tosmaller deflector and frame design. The lighter JL-14ESFR passed rough use and abuse test in the labs withoutplastic protectors.The Model JL-14 ESFR Sprinkler is FM approved[165°F (74°C) and 212°F (100°C) temperature ratingsonly] for use in buildings to 45 ft. (13.7m) high withstorage heights to 40 ft. (12.1m) when installed in accordancewith Factory Mutual Loss Prevention DataSheet 8-9 and Data Sheet 2-0 and other FM InstallationStandards.

Posted in ESFR K14 | Leave a comment